Telstra Communicare Installation Guide

Telstra Communicare Installation Guide


Getting Started

Before you get started, please ensure:

  • Your practice meets the requirements for running the Precedence Connector. See Technical Requirements
  • All Windows updates have been completed and up to date, systems rebooted where required
  • You have an unrestricted Windows account that allows you to install and configure the Precedence Connector on both the server and user workstations

 

Installation Checklist

Screen_Shot_2019-07-19_at_2.34.13_pm.png

A Bit of Background

The Precedence Connector integrates with Communicare. It must be installed locally on all required computers.

 Where more than one user requires the Precedence Connector, we recommend using Client-Server mode.

In Client-Server mode the Connector is first installed on the database server and adopts the role of the Precedence Server. All database and user settings are stored on the Precedence server.

Any remaining user workstations or terminal profiles can then be installed and configured to Client mode.

Where only one user requires the Precedence Connector software, Standalone mode is recommended as the operation mode. Here, database and user settings will be stored locally.

The import path is configured separately, via Communicare, at any stage. This step can be completed just once.

 

 

SERVER Installation

Download and Install Precedence Connector

  1. Download Connector application at https://inca.health/connector/download.html
  2. Run installation wizard
  3. Select Operation mode when prompted. Test and click Next 

Screen_Shot_2019-07-15_at_4.10.22_pm.png 

Screen_Shot_2020-04-29_at_1.30.26_pm.png 

 

Configure Database Settings

The database settings are configured in two stages. The first stage involves creating a new Communicare user to access the database. Ensure you take note of the username and password, as you will need to enter these details in the Precedence Connector in stage two.

 

  1. Navigate to User Groups and select the green to add user group Precedence Health Care
  2. Highlight Precedence Health Care and select the lower green to add user PHC_USER
  3. Set password and Close
  4. Configure access for PHC_USER by ticking the below options in each tab:
  • System Rights: Medication View
  • Viewing Rights: Care Plan, Common, Home and Community Care, Investigations View, Psychological and Social Problems
  • Program Rights: ALL
  • Formulary Rights: All Products
  1. Save

Screen_Shot_2019-07-15_at_4.35.34_pm.png

Screen_Shot_2019-07-15_at_4.35.56_pm.png

The second stage of configuring the database settings is completed directly in the Precedence Connector.
 
  1. Click the Precedence Conenctor icon in the taskbar and select Settings
  2. Navigate to the Clinical Software tab
  3. Ensure the Server name and Database folder have populated correctly
  4. Enter the user credentials of your new PHC_USER in the username and password sections 
  5. Test and Apply 

Screen_Shot_2019-07-15_at_4.41.30_pm.png

 

Configure User Settings 

  1. Click the Precedence Connector icon in the taskbar and select Settings
  2. Navigate to the Inca tab
  3. Select relevant user from the list of Communicare users and click Edit
  4. Enter the supplied Precedence username and password
  5. Save and Apply

Screen_Shot_2019-07-15_at_4.44.17_pm.png

 

Configure Import Path  

This step involves creating an alias of the existing Communicare Results folder titled IncaResults 

  1. Open ini file from Communicare Server Directory
  2. Search ResultFilePath to locate the Results import path and note this down
  3. Browse to the Results import path
  4. Right click on the folder -> Properties -> Sharing -> Advanced Sharing -> Add new shared name ‘IncaResults’ and grant Everyone full control of the folder via Permissions
  5. Apply and OK

Screen_Shot_2019-07-15_at_4.45.21_pm.png

 

Screen_Shot_2019-07-15_at_4.45.54_pm.png

Screen_Shot_2019-07-15_at_4.46.16_pm.png

 

 

CLIENT Installation

Download and Install Precedence Connector  

  1. Download Connector application at https://inca.health/connector/download.html
  2. Run installation wizard
  3. Select Operation mode when prompted. Enter the SERVER name, Test then click Next 

Screen_Shot_2020-04-29_at_2.38.25_pm.png

 

  

STANDALONE Installation

Please refer to SERVER installation instructions. Standalone is the default Operation mode so no Operation mode configuration is required here.

 

    • Related Articles

    • Health Care Homes Installation Guide for Telstra Communicare

      Download Risk Stratification Tool Installation Guide for Telstra Communicare Getting Started Before you get started, please ensure: Your practice meets the requirements for running the Precedence Connector. See Technical Requirements at ...
    • MedicalDirector Clinical Installation Guide

      Download MedicalDirector Clinical Installation Guide Getting Started Before you get started, please ensure: Your practice meets the requirements for running the Precedence Connector. See Technical Requirements All Windows updates have been completed ...
    • Zedmed Installation Guide

      Getting Started Before you get started, please ensure: Your practice meets the requirements for running the Precedence Connector. See Precedence Technical Requirements All Windows updates have been completed and up to date, systems rebooted where ...
    • Best Practice Installation Guide

        Getting Started Before you get started, please ensure: Your practice meets the requirements for running the Precedence Connector. See Technical Requirements All Windows updates have been completed and up to date, systems rebooted where required You ...
    • Medtech32 Installation Guide

        Getting Started Before you get started, please ensure: Your practice meets the requirements for running the Precedence Connector. See Technical Requirements All Windows updates have been completed and up to date, systems rebooted where required You ...